Showing 1–12 of 22 results
-
Save
20%
On RRP

Chauvin Arnoux PEL103 Power & Energy Logger
- Single-phase, split-phase and three-phase installations with or without a neutral, as well as other complex configurations.
- Voltage up to 1000V, Current up to 10,000A
- BlueTooth, Ethernet and USB communication
£1,910.00 £1,528.00 Inc VAT: £1,833.60
Add to basket -
Save
20%
On RRP

Chauvin Arnoux PEL103 Power & Energy Logger (inc. Clamps & Voltage Adaptor)
- Single-phase, split-phase and three-phase installations with or without a neutral, as well as other complex configurations.
- Voltage up to 1000V, Current up to 10,000A
- BlueTooth, Ethernet and USB communication
£2,881.00 £2,304.80 Inc VAT: £2,765.76
Add to basket -
Save
20%
On RRP

Chauvin Arnoux PEL103 Power & Energy Logger (inc. Clamps)
- Single-phase, split-phase and three-phase installations with or without a neutral, as well as other complex configurations.
- Voltage up to 1000V, Current up to 10,000A
- BlueTooth, Ethernet and USB communication
£2,660.00 £2,128.00 Inc VAT: £2,553.60
Add to basket -
Save
20%
On RRP

Chauvin Arnoux PEL104 WiFi Power & Energy Logger
- Five built-in communication interfaces: USB, Ethernet, Bluetooth, Wi-Fi, and 3G/GPRS
- Measures and logs the parameters required for energy consumption diagnostics
- Android application: monitor the PEL104 and modify its configuration remotely
- Compact and comprehensive instrument
- Four voltage inputs
- Three current inputs
- Measure and monitor all types of electrical networks: single-, split-, and three-phase systems
- Monitor circuits without cutting off the mains power supply
- Supplied with MA194-350 MiniFlex Clamps
- RMS and DC measurements (50Hz, 60Hz, and 400Hz) with 128 samples/cycles simultaneously on each phase
- Analogue readings
- Measure and characterise electric motors
- Measurements are conducted as per the IEEE 1459 standard
- Calculate total harmonic distortion for currents and voltages
- Breakdown of energy losses
- Voltage and current ratios facilitate the PEL104’s wide measurement range
- AC/DC voltage up to 1000V
- Current up to 10kA AC or 5kA DC
- Power (active, apparent, and reactive): 10 W/var/VA to 10 GW/Gvar/GVA
- Energy: 4 EWh/ 4 EVAh/ 4 EVarh
- Total energy (4 quadrants)
- Phase data: cos φ, tan Φ, power factor (PF)
- Harmonics up to the 50th order
- Crest factor
- Alarm mode with user-defined limits, an events log, and an email alert
- Measurements and calculations are recorded to the SD card
- SD card can store several years’ worth of data
- Supports continuous monitoring with a logging interval of 200ms per measurement
- Use PEL Transfer Software to analyse data, decompose the losses detected, and calculate the cost of power consumption
- Use DataView Software to create customised reports
- Portable
- Rugged
- Magnetised casing
- Self-powers via a voltage input (up to 600V)
- IP54
- Easy-to-read, backlit, triple display with an LCD screen
- Automatically recognises the type of sensor connected
- A compact, comprehensive, and convenient solution to monitoring and optimising energy efficiency
£2,432.00 £1,945.60 Inc VAT: £2,334.72
Add to basket -
Save
20%
On RRP

Chauvin Arnoux PEL104 WiFi Power & Energy Logger – Pro Kit
- Five built-in communication interfaces: USB, Ethernet, Bluetooth, Wi-Fi, and 3G/GPRS
- Measures and logs the parameters required for energy consumption diagnostics
- Android application: monitor the PEL104 and modify its configuration remotely
- Compact and comprehensive instrument
- Four voltage inputs
- Three current inputs
- Measure and monitor all types of electrical networks: single-, split-, and three-phase systems
- Monitor circuits without cutting off the mains power supply
- Supplied with MA194-350 MiniFlex Clamps
- RMS and DC measurements (50Hz, 60Hz, and 400Hz) with 128 samples/cycles simultaneously on each phase
- Analogue readings
- Measure and characterise electric motors
- Measurements are conducted as per the IEEE 1459 standard
- Calculate total harmonic distortion for currents and voltages
- Breakdown of energy losses
- Voltage and current ratios facilitate the PEL104’s wide measurement range
- AC/DC voltage up to 1000V
- Current up to 10kA AC or 5kA DC
- Power (active, apparent, and reactive): 10 W/var/VA to 10 GW/Gvar/GVA
- Energy: 4 EWh/ 4 EVAh/ 4 EVarh
- Total energy (4 quadrants)
- Phase data: cos φ, tan Φ, power factor (PF)
- Harmonics up to the 50th order
- Crest factor
- Alarm mode with user-defined limits, an events log, and an email alert
- Measurements and calculations are recorded to the SD card
- SD card can store several years’ worth of data
- Supports continuous monitoring with a logging interval of 200ms per measurement
- Use PEL Transfer Software to analyse data, decompose the losses detected, and calculate the cost of power consumption
- Use DataView Software to create customised reports
- Portable
- Rugged
- Magnetised casing
- Self-powers via a voltage input (up to 600V)
- IP54
- Easy-to-read, backlit, triple display with an LCD screen
- Automatically recognises the type of sensor connected
- A compact, comprehensive, and convenient solution to monitoring and optimising energy efficiency
£2,995.00 £2,396.00 Inc VAT: £2,875.20
Add to basket -
Save
20%
On RRP

Chauvin Arnoux PEL104 WiFi Power & Energy Logger (inc. Clamps)
- Five built-in communication interfaces: USB, Ethernet, Bluetooth, Wi-Fi, and 3G/GPRS
- Measures and logs the parameters required for energy consumption diagnostics
- Android application: monitor the PEL104 and modify its configuration remotely
- Compact and comprehensive instrument
- Four voltage inputs
- Three current inputs
- Measure and monitor all types of electrical networks: single-, split-, and three-phase systems
- Monitor circuits without cutting off the mains power supply
- Supplied with MA194-350 MiniFlex Clamps
- RMS and DC measurements (50Hz, 60Hz, and 400Hz) with 128 samples/cycles simultaneously on each phase
- Analogue readings
- Measure and characterise electric motors
- Measurements are conducted as per the IEEE 1459 standard
- Calculate total harmonic distortion for currents and voltages
- Breakdown of energy losses
- Voltage and current ratios facilitate the PEL104’s wide measurement range
- AC/DC voltage up to 1000V
- Current up to 10kA AC or 5kA DC
- Power (active, apparent, and reactive): 10 W/var/VA to 10 GW/Gvar/GVA
- Energy: 4 EWh/ 4 EVAh/ 4 EVarh
- Total energy (4 quadrants)
- Phase data: cos φ, tan Φ, power factor (PF)
- Harmonics up to the 50th order
- Crest factor
- Alarm mode with user-defined limits, an events log, and an email alert
- Measurements and calculations are recorded to the SD card
- SD card can store several years’ worth of data
- Supports continuous monitoring with a logging interval of 200ms per measurement
- Use PEL Transfer Software to analyse data, decompose the losses detected, and calculate the cost of power consumption
- Use DataView Software to create customised reports
- Portable
- Rugged
- Magnetised casing
- Self-powers via a voltage input (up to 600V)
- IP54
- Easy-to-read, backlit, triple display with an LCD screen
- Automatically recognises the type of sensor connected
- A compact, comprehensive, and convenient solution to monitoring and optimising energy efficiency
£2,838.00 £2,270.40 Inc VAT: £2,724.48
Add to basket -

Chauvin Arnoux PEL51 Power & Energy Logger
- Suitable for Single-phase installations.
- Connection via clamp without cutting off power supply
- Compact design of easy use and installation
£950.00 Inc VAT: £1,140.00
Add to basket -
Save
34%
On RRP
Fluke 1736 Three-Phase Power Logger – Gold Edition
- Fluke 1736/EUS Three-Phase Power Logger inc. Software
- 4x FREE Fluke 173X-flex1500 iFlexi 1500A Probes (12 inches)
- Fluke MP1-Magnetic Probe Set – Gold Edition ONLY
- Power Supply
- 4x Voltage Test Leads with Alligator Clips
- Soft Case
- Energy Analyse Plus Software
- Wi-Fi Adapter
- Line Cords
- Colour Coding Set
- USB Containing Instrument Documentation
£4,505.00 £2,995.00 Inc VAT: £3,594.00
Add to basket -

Fluke 3140R Clip On Current Transformer
- CT Type – Clamp On
- Current Range – 2 to 400Amps
- Accuracy – 2 percent RDG +/- 0.04 Amps
- Frequency Response – 20 KiloHertz
- Jaw Opening – 3.2 centimeters (1.25 inches)
£533.00 Inc VAT: £639.60
Add to basket -

Fluke BP1730 Li-Ion Battery Pack 3.7V
- Li Ion Battery Pack for the Fluke 1730
- Voltage: 3.7V
- Milliamps-per-hour: 2500mAh
£52.00 Inc VAT: £62.40
Add to basket -

Fluke MP1 Magnet Probes
- Magnetic Probes Tips
- Set of 4
- For 4MM Banana
- Very useful for control system monitoring
- No need to disconnect wiring or use cumbersome clip leads
£115.00 Inc VAT: £138.00
Add to basket -
Save
15%
On RRP

Fluke VR1710 Single-Phase Voltage Quality Recorder
- Plugs directly into a mains socket and monitors voltage quality
- Monitor trends, dropouts and power quality
- Easy to use
- Continuous recording
- Graphical summary of data and quick overview of problems
- Records for up to 339 days
- MIN/MAX/AVG value calculation
- Actual transient display
- Flicker recording
- Individual harmonics and THD value recording
- Statistical analysis of single phase voltage events
- Compatible with PowerLog software (included)
£998.00 £848.30 Inc VAT: £1,017.96
Add to basket