01785 600 691enquiries@thecalcentre.co.uk

Save

17%

On RRP

Fluke i30s AC/DC Current Clamp (30A)

Original price was: £774.00.Current price is: £642.42. Inc VAT: £770.90

    Available on back-order

    SKU FLUKE i30s Categories , Brand:

    Description

    Fluke i30s AC/DC Current Clamp (30A)

    The Fluke i30s AC/DC Current Clamp (30A) is used to measure AC/DC current and complex waveform currents.

    It is not a clamp meter, but is an optional current module that is designed for direct attachment to Fluke oscilloscopes and digital multimeters in order to carry out current measurements up to 30A.

    The jaws of this clamp are 19mm in diameter.

    • Very accurate
    • Flexible current range
    • Compatible with other recording instruments

    Fluke i30s Technical Specifications

    Specified current range
     30 mA to 30A dc, 30 mA to 20 A ac rms
    Usable current range
     5 mA to 30 A dc, 30 mA to 20 A ac rms
    Crest Factor
     1.4″
    Output sensitivity
     100 mV/A
    Accuracy (at 25 °C)
     ± 1 % of reading ± 2 mA
    Resolution
     ± 1 mA
    Load impedance
     > 100 kΩ
    Conductor position sensitivity
     ± 1 % relative to center reading
    Frequency range
     DC to 100 kHz (- 0.5 dB)
    Phase shift below 1 kHz
     < 2 degrees
    Temperature coefficient
     ± 0.01 % of reading/°C
    Power supply
     9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
    Working voltage (see Safety Standards section)
     300 V ac rms or dc
    General specifications
    Maximum conductor size
     19 mm diameter
    Output connection
     Safety BNC connector, supplied with safety 4 mm adapter
    Output zero
     Manual adjust via thumbwheel
    Cable length
     2 meters
    Operating temperature range
     0 °C to 50 °C
    Storage temperature range (with battery removed)
     -20 °C to 85 °C
    Operating humidity
     15 % to 85 % (non-condensing)
    Weight
     250 g
    Safety standards
     BS EN 61010-1: 2001
     BS EN 61010-2-032: 2002
     BS EN 61010-031: 2002
     300 Vrms, Category III, Pollution Degree 2
     Use of the probe on uninsulated conductors is limited to 300 V acrms or dc and frequencies below 1 kHz.
    EMC Standards
     EN 61326: 1998 A1, A2, & A3
    • Very accurate
    • Flexible current range
    • Compatible with other recording instruments