Save

37%

On RRP

Fluke 1673FC Multifunction Tester

Original price was: £1,959.00.Current price is: £1,225.00. Inc VAT: £1,470.00

    Available on back-order

    Calibration Certificate

    Add a 12 month Calibration Certificate

    Description

    Fluke 1673FC Multifunction Tester

    The Fluke 1670 Series Multifunction Installation Testers will revolutionize the way you work. With an ergonomic design, seamless user interface, integrated data management capabilities, wireless connectivity (1673 FC and 1674 FC), and comprehensive reporting software, the 1670 Series sets the new standard for an integrated installation testing solution.

    Reliable installation testing is essential for ensuring the safety, optimal functionality, and integrity of a facility’s electrical systems. The 1670 Series’ rugged design allows you to verify the safety of electrical installations in domestic, commercial, and industrial applications while meeting the requirements of IEC/HD 60364-6 and all relevant local installation test standards.

    With the 1670 Series, you’ll be able to perform your required testing faster and reduce the time you spend on documentation, all while having the ultimate confidence in the data you’re collecting.

    Simplified User Interface and Testing Setup

    The 1670 Series takes data management to the next level streamlining test set up and preparation with an advanced bidirectional user interface. When setting up your project, the hierarchical tree topology for clients, sites, distribution boards, circuits, and test points can be easily customized using the high-resolution colour touchscreen, a smart device, or by PC. Edit, add, delete, or modify information directly on the tool as you test to ensure accurate data, or transfer updates to your tester via the Fluke Connect™️ mobile app or TruTest™️ desktop software. Easy-to-read test tables help you quickly see that you are capturing the right measurement data at the right test point, every time. Now you can spend less time setting up your tester and organizing data, giving you more time to perform valuable testing.

     

     

     

     

     

     

     

     

     

     

     

     

     

    Fluke TruTest Software

    An intuitive interface and live onscreen dashboard make it quick and simple to see the status of all your clients. Customer information may be inputted directly on the software; uploaded with test results from the 1673FC via a USB-C interface; or downloaded from the Fluke Connect App. A user-friendly report builder formats this data into a test certificate complete with your company logo and signature. Fluke’s TruTest Software allows you to create reports compliant with the following regional standards:

    • BS7671
    • DIN VDE 0100-600
    • ÖVE/ÖNORM 8101
    • NIN/NIV
    • NEN3140

    It also includes a pre-configured international report template and is updated as necessary to accommodate additional regional standards.

    Additionally, Fluke’s TruTest Software can be used with other Fluke instruments, allowing you to manage multiple data sets in one place. As a result, you can incorporate measurements gathered using auxiliary Fluke tools into your reports.

    Fluke Connect App

    Compatibility with the Fluke Connect App not only reduces documenting time but optimises testing efficiency too. The Fluke Connect App wirelessly synchronises data saved to the Fluke 1673FC to your Cloud storage for fast download to the TruTest Software. Furthermore, photos of faults or assets can be assigned to specific test points along with necessary notes. In addition to this, as the Fluke Connect App is compatible with an array of Fluke Tools, such as the Fluke 1630-2 ground clamp, you can also incorporate data from these auxiliary tools into the test point record, allowing you to provide a clearer picture of a facility’s health.

    Finally, to streamline data management and maximise testing efficiency, the Fluke Connect App includes an option to create and upload projects, as well as distribution boards and circuits, to the Fluke 1673FC. These guide you through testing, streamlining testing and data management.

    Fluke 1673 Multifunction Tester Kit Options

    The Fluke 1673 Multifunction Tester is available as a standalone multifunction electrical tester or as part of a kit.

    FLUKE-1673FLUKE-1673/FTT
    Fluke 1673 FC Multifunction Tester
    Heavy Duty Mains Cord with Single Input Connector
    USB-C Power Adapter for Charging
    Remote Control Probe
    Zero Adapter
    Test Leads and Probes
    Alligator Clips
    Li-Ion Battery
    Hanging Strap
    Hard Case
    TruTest Software

    Key Features

    • Mid-range model in Fluke’s 1670 series of multifunction installation testers
    • Best-in-class multifunction electrical tester
    • Perfect for troubleshooting and verifying the installation and functionality of electrical installations and EV chargers
    • 30% faster testing
    • Reduce documentation time by up to 50%
    • NEW Voltage Drop Test
    • NEW EV Test 6mA for RCD A/EV, RDC-DD
    • NEW automatic PASS/FAIL assessment
    • NEW automatic measurement validation
    • AC/DC Voltage
    • Continuity with low test current (10mA) to measure motor windings
    • Insulation
    • Non-trip Loop
    • High Current Loop with mOhm resolution
    • RCD Trip
    • RCD Ramp
    • RCD trip current and trip time measured in parallel (RCD type AC, A, B, F and GFCI)
    • PEFC or PSC and loop impedance measured in parallel
    • Phase Rotation
    • Earth Ground Resistance
    • Earth volt touchpad detects raised earth voltages (>50V) indicating potentially dangerous situations
    • Auto Test
    • Help function provides visual connection guides
    • Input and edit site information directly on the tester, via the TruTest Software, or Fluke Connect App
    • Easy-to-read measurement tables
    • Data and metadata are automatically saved to relevant test points, eliminating double-entry
    • Z Max memory for loop tests
    • Zero adapter
    • Ring testing
    • Magnetic hanging kit (sold separately) enables hands-free operation
    • 180° rotating screen
    • Full-colour touchscreen
    • Rotary knob for fast navigation
    • Create reports using Fluke’s TruTest Software
    • TruTest Software offers an intuitive interface and live dashboard for managing clients
    • Input client information directly into the software
    • Download client information and test results from the Fluke 1673 or Fluke Connect App
    • Create reports compliant with an array of regional standards
    • Pre-configured international report template
    • TruTest is compatible with other Fluke instruments allowing you to manage and format data in one place
    • Compatible with the Fluke Connect App
    • Fluke Connect synchronises data saved on the tester with the Cloud
    • Attach photos to test points using the Fluke Connect App
    • Save data gathered using other Fluke Connect-enabled tools to the test point record
    • Create projects, distribution boards, and circuits in the Fluke Connect App to be uploaded to the tester
    • USB-C interface
    • Wireless Bluetooth interface
    • Rugged design
    • Meets IEC/HD 60364-6
    • Field upgradeable
    • Compact
    • Lightweight
    • Rechargeable 2500 mAh Li-Ion battery
    • Ideal for domestic and light commercial electricians, maintenance technicians, mid-volume condition reporters, new build commissioners, and res-comm condition reporters

    Fluke 1673FC Multifunction Tester Comparison Chart

    167216731674
    Full-colour touch screen
    Insulation PreTest safety function
    Insulation at L-N, L-PE, N-PE inputs
    Auto Test sequence
    Auto pass/fail results
    Loop and line impedance — mΩ resolution
    Continuity at L-N, L-PE, N-PE inputs
    Test smooth DC sensitive RCDs (Type B/B+)
    Earth resistance
    Voltage AC, DC, and frequency
    Wiring polarity checker, detects broken PE and N wires
    Insulation resistance
    Continuity and resistance
    Measure motor windings with continuity test (@ 10 mA)
    Loop and line impedance
    Prospective Earth Fault Current (PEFC/IK)
    Prospective Short-Circuit Current (PSC/IK)
    RCD trip time
    RCD trip current (ramp test)
    Measures trip time and current for RCD type AC, A,
    and F in one test
    RCD variable test current
    Automatic RCD test sequence
    Phase sequence test
    Voltage drop measurement
    Insulation Monitoring Device (IMD) test
    Surge Protection Device (SPD) test
    Other Features
    Fluke Connect compatibility
    Fluke Cloud storage
    On/Off switchable Auto Start for continuity, RCD,
    and loop test
    Illuminated display
    Memory, Interface
    Z Max memory
    Memory
    USB-C, and BLE interfaceUSB-CUSB-C/BLEUSB-C/BLE
    General Specifications
    Size26.25 cm x 14.19 cm x 11.93 cm (10.3 in x 5.6 in x 4.7 in)
    Weight (incl. batteries)1.6 kg (3.5 lb)
    Battery size, quantityBP290, Li-ion, 10.8 V, 2500 mAh, 27 Wh
    Ingress ProtectionIEC 60529: IP40
    SafetyComplies with IEC/EN 61010-1, IEC 61010-2-030, IEC 61010-2-03
    Safety ratingCAT III 600 V, CAT IV 300 V
    PerformanceIEC 61557-1 to IEC/EN 61557-8 and IEC 61557-10
    • Mid-range model in Fluke’s 1670 series of multifunction installation testers
    • Input and edit site information directly on the tester, via the TruTest Software, or Fluke Connect App
    • Perfect for troubleshooting and verifying the installation and functionality of electrical installations and EV chargers
    • Best-in-class multifunction electrical tester
    • 30% faster testing
    • Reduce documentation time by up to 50%
    • NEW Voltage Drop Test
    • NEW EV Test 6mA for RCD A/EV, RDC-DD
    • NEW automatic PASS/FAIL assessment
    • NEW automatic measurement validation
    • AC/DC Voltage
    • Continuity with low test current (10mA) to measure motor windings
    • Insulation
    • Non-trip Loop
    • High Current Loop with mOhm resolution
    • RCD Trip
    • RCD Ramp
    • RCD trip current and trip time measured in parallel (RCD type AC, A, B, F and GFCI)
    • PEFC or PSC and loop impedance measured in parallel
    • Phase Rotation
    • Earth Ground Resistance
    • Earth volt touchpad detects raised earth voltages (>50V) indicating potentially dangerous situations
    • Auto Test
    • Help function provides visual connection guides
    • Easy-to-read measurement tables
    • Data and metadata are automatically saved to relevant test points, eliminating double-entry
    • Z Max memory for loop tests
    • Zero adapter
    • Ring testing
    • Magnetic hanging kit (sold separately) enables hands-free operation
    • 180° rotating screen
    • Full-colour touchscreen
    • Rotary knob for fast navigation
    • Create reports using Fluke’s TruTest Software
    • TruTest Software offers an intuitive interface and live dashboard for managing clients
    • Input client information directly into the software
    • Download client information and test results from the Fluke 1673 or Fluke Connect App
    • Create reports compliant with an array of regional standards
    • Pre-configured international report template
    • TruTest is compatible with other Fluke instruments allowing you to manage and format data in one place
    • Compatible with the Fluke Connect App
    • Fluke Connect synchronises data saved on the tester with the Cloud
    • Attach photos to test points using the Fluke Connect App
    • Save data gathered using other Fluke Connect-enabled tools to the test point record
    • Create projects, distribution boards, and circuits in the Fluke Connect App to be uploaded to the tester
    • USB-C interface
    • Wireless Bluetooth interface
    • Rugged design
    • Meets IEC/HD 60364-6
    • Field upgradeable
    • Compact
    • Lightweight
    • Rechargeable 2500 mAh Li-Ion battery
    • Ideal for domestic and light commercial electricians, maintenance technicians, mid-volume condition reporters, new build commissioners, and res-comm condition reporters
    • Specifications: Fluke 1670 Series Multifunction Installation Testers

      General Specifications

      SpecificationCharacteristic
      Size26.25 cm x 14.19 cm x 11.93 cm (10.3 in x 5.6 in x 4.7 in)
      Weight (incl. batteries)1.6 kg (3.5 lb)
      Battery size, quantityBP290, Li-ion, 10.8 V, 2500 mAh, 27 Wh
      Ingress ProtectionIEC 60529: IP40
      SafetyComplies with IEC/EN 61010-1, IEC 61010-2-030, IEC 61010-2-034
      Safety ratingCAT III 600 V, CAT IV 300 V
      PerformanceIEC 61557-1 to IEC/EN 61557-8 and IEC 61557-10

      Voltage measurement AC, DC, and frequency

      RangeResolutionInput ImpedanceOverload Protection
      600 V0.1 V320 kΩ660 V
      45-66 Hz0.1 Hz320 kΩ

      Continuity testing (RLO)

      Range (Auto ranging)ResolutionOpen Circuit Voltage
      20 Ω/200 Ω/2000 Ω0.01 Ω/0.1 Ω/1 Ω> 4 V

      Insulation resistance measurement (RISO)

      Test voltages
      1672100-250-500-1000 V
      1673 FC/1674 FC50-100-250-500-1000 V
      Test VoltageInsulation Resistance RangeResolutionTest Current
      50 V10 kΩ to 50 MΩ0.01 MΩ1 mA @ 50 kΩ
      100 V10 kΩ to 20 MΩ
      20 MΩ to 100 MΩ
      0.01 MΩ
      0.1 MΩ
      1 mA @ 100 kΩ
      250 V10 kΩ to 20 MΩ
      20 MΩ to 200 MΩ
      0.01 MΩ
      0.1 MΩ
      1 mA @ 250 kΩ
      500 V10 kΩ to 20 MΩ
      20 MΩ to 200 MΩ
      200 MΩ to 500 MΩ
      0.01 MΩ
      0.1 MΩ
      1 MΩ
      1 mA @ 500 kΩ
      1000 V100 kΩ to 200 MΩ
      200 MΩ to 1000 MΩ
      0.1 MΩ
      1 MΩ
      1 mA @ 1 MΩ

      Insulation pretest

      Insulation safety pretestConnections from the Tester to L, N, and PE are required.


      Insulation pretestSurge Protection Device (SPD) Insulation RAMP Test (Varistor Test) IEC 61643-11

      Test VoltageVoltage RangesResolutionTest CurrentAccuracy
      500 VStep Ramp 0 V to 500 V1 V1 mA± (1.5 % + 3 digits)
      1000 VStep Ramp 0 V to 1000 V1 V1 mA± (1.5 % + 3 digits)

       

      Insulation Monitoring Devices (IMD) IEC 61557-8

      RangeResolutionNote
      1 kΩ to 10 kΩ1 kΩ> 1 MΩ only available with voltages >100 V
      10 kΩ to 100 kΩ10 kΩ
      100 Ω to 3 MΩ100 kΩ

      Loop and line impedance (ZI No Trip and Hi Current)

      Range SettingResolutionAccuracy[1]
      10 Ω[2]0.001 ΩHi Current mΩ mode: ± (2 % + 15 digits) No Trip (2&3 wire) mode: ± (3 % + 6 digits)
      20 Ω0.01 ΩHi Current mode: ± (2 % + 4 digits)
      200 Ω0.1 ΩNo Trip mode: ± (3 %)
      Hi Current mode: ± (2 %)
      2000 Ω1 Ω± 6 %[3]
      1. Valid for resistance of neutral circuit < 20 Ω and up to a system phase angle of 30°. Test leads must be zeroed before testing.
      2. Fluke Connect™ 1674 FC model only.
      3. Valid for mains voltage > 200 V.

      Prospective Earth Fault Current (PEFC) Prospective Short Circuit Current (PSC)

      RangeResolutionUnits
      0 kA to 50 kAIK < 1000 A
      IK ≥ 1000 A
      1 A
      0.1 kA

      Computation: Prospective Earth Fault Current (PEFC/IK) or prospective short circuit current (psc/IK) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.

      Voltage drop (by line impedance test)

      RangeResolutionAccuracy
      0.0-99.9%0.1%Consider accuracy of line
      impedance measurement(s)

      Note: Voltage drop reading is calculated from line impedance measurement & entered current rating

      RCD tests, RCD types tested

      RCD Type[1]16721673 FC1674 FC
      AC[2]G[3]
      ACS[4]
      A[5], F[6]G
      A, FS
      B, B+[7]G
      B, B+S
      RDC-DD, RCD A/EV, RCD B/Mi[8]
      GFCI
      1. RCD test inhibited for V > 265 AC
      2. RCD tests permitted only if the selected current, multiplied by earthing resistance, is < 50 V.
      3. AC – Responds to AC
      4. G – General, no delay
      5. S – Time delay
      6. A – Responds to AC and pulsed signal
      7. F – responds to AC, pulsed and high frequency
      8. B, B+ – Responds to AC, pulsed, high frequency, and smooth DC
      9. RDC-DD – Responds to residual currents of 6 mA DC

      RCD tripping time test (ΔT)


      Test Function
      RCD Current Selection
      10 mA30 mA100 mA[1]300 mA[1]500 mA[1]1000 mA[2]Var[3]
      x½, 1
      x5
      Ramp
      Auto

      Mains voltage 50 V – 265 V ac, 45/66 Hz

      1. Type B RCDs require mains voltage range of 195 V to 265 V.
      2. Type AC RCDs only.
      3. Type A RCDs are limited to 700 mA, not available for Type B RCDs.

      RCD Tripping Current (IΔN) Measurement/Ramp Test


      Current Range

      Step Size
      Dwell TimeMeasurement Accuracy
      Type GType S
      30 % to 110 % of RCD-rated current[1]10 % of IΔN [2]300 ms/step500 ms/step± 5 %

      1. Specified trip current ranges (IEC 61008-1):

               30 % to 150 % for Type A IΔ N > 10 mA
      30 % to 210 % for Type A IΔ N = 10 mA
      20 % to 210 % for Type B
      50 % to 100 % for Type AC
      35 % to 140 % for Type A (> 10 mA)
      35 % to 200 % for Type A (£ 10 mA)
      50 % to 200 % for Type B2. 5 % for Type B


      Earth resistance test (RE) 1673 FC and 1674 FC only

      RangeResolutionFrequencyOutput Voltage
      200 Ω/2000 Ω0.1 Ω/1 Ω128 Hz25 V

      Phase sequence indication

      Icon RangeDisplay
      Phase Sequence indicator is active185 V to 600 V“1-2-3”: or “3-2-1” for incorrect phase

    Fluke 167x series Data Sheet

    Fluke 167x series Product Specifications

    Fluke 167x series Users Manual