    DiLog DL9130 & DLEV1 EVSE Kit

    The DiLog EVSE Kit combines a DL9130 multifunction tester and a DiLog DLEV1 adapter to provide a comprehensive kit for all installation testing, especially those with electrical vehicle charging points. Whether these are installed with Type B RCD’s or with 6mA residual direct current devices and in either TN or TT configurations, this kit gives you the flexibility to test for electrical safety as well as EVSE functionality.

    This unit is currently available to pre-order – first deliveries expected June!

    This is a simple to use manual tester that has all the functions of the more expensive testers but at a much more affordable price!

    • EV Auto RCD Sequence
    • Type AC, A, B & Selective RCDs
    • 6mA RDC-DD for EV Testing
    • Variable RCD Test
    • Rmax and Zmax Feature
    • Intelligent Auto Sensing High
    • Current 2 & 3 Wire Loop Test
    • New Colour Changing RGB Display
    • Selectable 15/200mA Continuity Test
    • Remote Test Probe
    • Full UKAS Calibration Certificate

    DL9130EV Kit user shot

    DL9100 Series MFT Technical Information

    Voltage  
      DL9110 DL9118 DL9120 DL9130EV
    Display Range 0V to 440V 0V to 480V
    Measuring Range 0V to 440V 0V to 480V
    Voltage Accuracy +/- 5% +/- 2digits +/- 5% +/- 2digits

     

    Continuity  
      DL9110 DL9118 DL9120 DL9130EV
    Display Range (200mA) 0.01Ω to 200Ω 0.01Ω to 2000Ω
    Measuring Range (200mA) 0.10Ω to 200Ω 0.10Ω to 2000Ω
    Accuracy +/- 2% +/- 5 digits
    Resolution 0.01Ω to 1.99Ω

    2.0Ω to 19.9Ω

    20Ω to 200Ω

    0.01Ω to 19.99Ω

    20.0Ω to 199.9Ω

    200Ω to 2000Ω

    Test Voltage >4Vdc >25Vdc Open Circuit
    Test Current >200mA
    Display Range (15mA) 0.01Ω to 200Ω
    Accuracy +/- 2% +/- 5 digits

     

    Insulation      
      DL9110 DL9118 DL9120 DL9130EV
    Display Range 0.01MΩ to 200MΩ
    Display Range 0.05MΩ to 200MΩ
    Accuracy +/-5% +/-5 digits
    Alarm Warning <1MΩ Audible <1MΩ Screen & Audible
    Test Voltage 250/500 250/500/1000V

     

    No Trip Loop Impedance  
      DL9110 DL9118 DL9120 DL9130EV
    Supply voltage 195-253V, 45Hz – 65Hz
    Display Range 0.01Ω to 2000Ω
    Measuring Range 1.00 to 1999Ω (non-trip)
    Accuracy +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)
    Test Current <15mA RMS

     

    High Current Loop Impedance  
      DL9110 DL9118 DL9120 DL9130EV
    Supply voltage 195-253V, 45Hz – 65Hz
    Display Range 0.01Ω to 2000Ω
    Measuring Range 0.10Ω to 1999Ω (high current)
    Accuracy +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)
    Test Current 3A RMS

     

    Loop Test PFC Measurement  
      DL9110 DL9118 DL9120 DL9130EV
    Display Range 1A to 26kA 0.1A to 26.0kA
    Accuracy +/-5%  +/-5 digits +/-5%  +/-5 digits

     

    High Current Line Impedance    
      DL9110 DL9118 DL9120 DL9130EV
    Display Range 0.01Ω to 2000Ω 0.01Ω to 2000Ω
    Measuring Range 0.10Ω to 2000Ω 0.10Ω to 2000Ω
    Accuracy +/-5% +/-5 digits +/-5% +/-5 digits
    Test Current 3A RMS Peak

     

    Line Test PSC Measurement  
      DL9110 DL9118 DL9120 DL9130EV
    Range 1A to 26kA 0.1A to 26.0kA
    Accuracy +/-5%  +/-5 digits +/-5%  +/-5 digits

     

    RCD Trip Time Test  
      DL9110 DL9118 DL9120 DL9130EV
    Supply Voltages 195-253V, 45Hz – 65Hz
    RCD Types AC, A & Selective AC, A, B & Selective
    Nominal Test Current 10mA/30mA/100mA ( ½ , 1, 5 I∆n)

    300mA/500mA ( ½, 1 I∆n)

    10mA/30mA/100mA ( ½ , 1, 5 I∆n)

    300mA/500mA ( ½, 1 I∆n)

    Variable Mode

    Variable RCD Test 1mA – 500mA
    Test Current Accuracy -0% +10% at I∆n and 5I∆n

    -0% +10% at ½ I∆n

    Trip Time Ranges 0 to 2000ms ½ I∆n

    0ms – 300ms I∆n general

    0ms – 500ms I∆n selective

    0 to 40ms 5 I∆n

    Trip Time Accuracy +/- 5% +/- 2 digits
    Nominal Test Current 10mA/30mA/100mA ( ½ , 1, 5 I∆n)

    300mA/500mA ( ½, 1 I∆n)

     

    RDC-DD Trip Time Test  
      DL9110 DL9118 DL9120 DL9130EV
    Supply Voltages 195-253V, 45Hz – 65Hz
    Current Type DC
    Nominal Test Current 6mA
    Test Current Accuracy -0% +10%
    Trip Time Ranges 0 to 10000 I∆n
    Trip Time Accuracy +/- 5% +/- 2 digits
    Ramp Test Current Range 2mA – 10mA

     

    RCD (Ramp) Trip Current Test  
    Range 0.5 I∆n to 1.1 I∆n
    Range (6mA DC) 0.1mA to 10mA

    (over 30 seconds)

    Accuracy +/-5% of the expected current
    Step Size 0.1*∆n

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    • EV Auto RCD Sequence
    • Type AC, A, B & Selective RCDs
    • 6mA RDC-DD for EV Testing
    • Variable RCD Test
    • Rmax and Zmax Feature
    • Intelligent Auto Sensing High
    • Current 2 & 3 Wire Loop Test
    • New Colour Changing RGB Display
    • Selectable 15/200mA Continuity Test
    • Remote Test Probe
    • Full UKAS Calibration Certificate
    • Multifunction Tester
    • Padded neck strap
    • Professional toolbox style carry case
    • Mains lead
    • 3 Wire Test Leads with crocs & probes
    • 6 x AA Batteries
    • Operating manual
    • UKAS Calibration Certificate

    DL9130 Datasheet

    Di-LOG EV Range PDF