Description
DiLog DL9130 & DLEV1 EVSE Kit
The DiLog EVSE Kit combines a DL9130 multifunction tester and a DiLog DLEV1 adapter to provide a comprehensive kit for all installation testing, especially those with electrical vehicle charging points. Whether these are installed with Type B RCD’s or with 6mA residual direct current devices and in either TN or TT configurations, this kit gives you the flexibility to test for electrical safety as well as EVSE functionality.
This unit is currently available to pre-order – first deliveries expected June!
This is a simple to use manual tester that has all the functions of the more expensive testers but at a much more affordable price!
- EV Auto RCD Sequence
- Type AC, A, B & Selective RCDs
- 6mA RDC-DD for EV Testing
- Variable RCD Test
- Rmax and Zmax Feature
- Intelligent Auto Sensing High
- Current 2 & 3 Wire Loop Test
- New Colour Changing RGB Display
- Selectable 15/200mA Continuity Test
- Remote Test Probe
- Full UKAS Calibration Certificate
DL9100 Series MFT Technical Information
Voltage | ||||
DL9110 | DL9118 | DL9120 | DL9130EV | |
Display Range | 0V to 440V | 0V to 480V | ||
Measuring Range | 0V to 440V | 0V to 480V | ||
Voltage Accuracy | +/- 5% +/- 2digits | +/- 5% +/- 2digits |
Continuity | ||||
DL9110 | DL9118 | DL9120 | DL9130EV | |
Display Range (200mA) | 0.01Ω to 200Ω | 0.01Ω to 2000Ω | ||
Measuring Range (200mA) | 0.10Ω to 200Ω | 0.10Ω to 2000Ω | ||
Accuracy | +/- 2% +/- 5 digits | |||
Resolution | 0.01Ω to 1.99Ω
2.0Ω to 19.9Ω 20Ω to 200Ω |
0.01Ω to 19.99Ω
20.0Ω to 199.9Ω 200Ω to 2000Ω |
||
Test Voltage | >4Vdc >25Vdc Open Circuit | |||
Test Current | >200mA | |||
Display Range (15mA) | 0.01Ω to 200Ω | |||
Accuracy | +/- 2% +/- 5 digits |
Insulation | |||||||
DL9110 | DL9118 | DL9120 | DL9130EV | ||||
Display Range | 0.01MΩ to 200MΩ | ||||||
Display Range | 0.05MΩ to 200MΩ | ||||||
Accuracy | +/-5% +/-5 digits | ||||||
Alarm Warning | <1MΩ Audible | <1MΩ Screen & Audible | |||||
Test Voltage | 250/500 | 250/500/1000V | |||||
No Trip Loop Impedance | ||||
DL9110 | DL9118 | DL9120 | DL9130EV | |
Supply voltage | 195-253V, 45Hz – 65Hz | |||
Display Range | 0.01Ω to 2000Ω | |||
Measuring Range | 1.00 to 1999Ω (non-trip) | |||
Accuracy | +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω) | |||
Test Current | <15mA RMS |
High Current Loop Impedance | ||||
DL9110 | DL9118 | DL9120 | DL9130EV | |
Supply voltage | 195-253V, 45Hz – 65Hz | |||
Display Range | 0.01Ω to 2000Ω | |||
Measuring Range | 0.10Ω to 1999Ω (high current) | |||
Accuracy | +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω) | |||
Test Current | 3A RMS |
Loop Test PFC Measurement | ||||
DL9110 | DL9118 | DL9120 | DL9130EV | |
Display Range | 1A to 26kA | 0.1A to 26.0kA | ||
Accuracy | +/-5% +/-5 digits | +/-5% +/-5 digits |
High Current Line Impedance | |||||
DL9110 | DL9118 | DL9120 | DL9130EV | ||
Display Range | 0.01Ω to 2000Ω | 0.01Ω to 2000Ω | |||
Measuring Range | 0.10Ω to 2000Ω | 0.10Ω to 2000Ω | |||
Accuracy | +/-5% +/-5 digits | +/-5% +/-5 digits | |||
Test Current | 3A RMS Peak | ||||
Line Test PSC Measurement | ||||
DL9110 | DL9118 | DL9120 | DL9130EV | |
Range | 1A to 26kA | 0.1A to 26.0kA | ||
Accuracy | +/-5% +/-5 digits | +/-5% +/-5 digits |
RCD Trip Time Test | ||||
DL9110 | DL9118 | DL9120 | DL9130EV | |
Supply Voltages | 195-253V, 45Hz – 65Hz | |||
RCD Types | AC, A & Selective | AC, A, B & Selective | ||
Nominal Test Current | 10mA/30mA/100mA ( ½ , 1, 5 I∆n)
300mA/500mA ( ½, 1 I∆n) |
10mA/30mA/100mA ( ½ , 1, 5 I∆n)
300mA/500mA ( ½, 1 I∆n) Variable Mode |
||
Variable RCD Test | 1mA – 500mA | |||
Test Current Accuracy | -0% +10% at I∆n and 5I∆n
-0% +10% at ½ I∆n |
|||
Trip Time Ranges | 0 to 2000ms ½ I∆n
0ms – 300ms I∆n general 0ms – 500ms I∆n selective 0 to 40ms 5 I∆n |
|||
Trip Time Accuracy | +/- 5% +/- 2 digits | |||
Nominal Test Current | 10mA/30mA/100mA ( ½ , 1, 5 I∆n)
300mA/500mA ( ½, 1 I∆n) |
RDC-DD Trip Time Test | ||||
DL9110 | DL9118 | DL9120 | DL9130EV | |
Supply Voltages | 195-253V, 45Hz – 65Hz | |||
Current Type | DC | |||
Nominal Test Current | 6mA | |||
Test Current Accuracy | -0% +10% | |||
Trip Time Ranges | 0 to 10000 I∆n | |||
Trip Time Accuracy | +/- 5% +/- 2 digits | |||
Ramp Test Current Range | 2mA – 10mA |
RCD (Ramp) Trip Current Test | ||
Range | 0.5 I∆n to 1.1 I∆n | |
Range (6mA DC) | 0.1mA to 10mA
(over 30 seconds) |
|
Accuracy | +/-5% of the expected current | |
Step Size | 0.1*∆n |