Fluke i2000 Flexible Current Clamp (2000 A)

Original price was: £421.00.Current price is: £349.43. Inc VAT: £419.32

    Available on back-order

    SKU FLUKE i2000 Categories , Brand:

    Description

    Fluke i2000 Flexible Current Clamp (2000 A)

    This Fluke i2000 Flexible Current Clamp (2000 A) is a flexible AC current measurement tool that can be used to attach to difficult applications that conventional clamp meters would struggle with. Shipping as standard with flexible cabling, the i2000 can bend around practically any application in order to measure current across three ranges of 20A, 200A and 2000A.

    This clamp is not actually a meter – it is designed to be used with multimeters, recorders or data loggers to give these devices the ability to carry out measurements of current.

    The clamp has maximum conductor diameter of 178mm and is CAT III 600V safety rated.

    Fluke i2000 Technical Specifications

    Current ranges
     20 A
     200 A
     2000 A
     AC rms
    Output sensitivity (AC-coupled)
     100 mV
     10 mV
     1 mV
     1 mV per A
    Load impedance
     100 kΩ minimum
    Accuracy
    at 25 °C ± 1 % of range (45 Hz to 65 Hz)
    Linearity
    10 % to 100 % of range ± 0.2 % of reading
    Noise
     8 mV ac rms (30 A)
     2 mV ac rms (300 A, 3000 A)
    Frequency range
     10 Hz to 20 kHz (-3 dB)
    Phase error
     < ± 1 º (45 Hz to 65 Hz)
     ± 10 º (at 20 kHz)
    Position sensitivity
    with cable > 25 mm from the coupling ± 2 % of range
    External field
    with cable > 200 mm from the head ± 1 % of range
    Power supply
     2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
    Temperature Coefficient
     ± 0.08% of reading per°C
    Working voltage
    see Safety standards section 600 V AC rms or DC

     

    General Specifications
    Head Circumference
     610 mm (24 in)
    Head cable diameter
     14.3 mm (0.56 in)
    Head bend radius
     38.1 mm (1.5 in)
    Cable length (head to electronics)
     2 m (6.56 ft)
    Output connection
     Molded 4 mm safety plugs (not integrated)
    Operating temperature range
     0 °C to 70 °C (32 °F to 158 °F) (head and electronics)
    Storage temperature range
     -40 °C to 105 °C (-40 °F to 221 °F) (head)
     -20 °C to 85 °C (-4 °F to 185 °F) (electronics)
    Operating humidity
     15 % to 85 % (non-condensing)
    Weight
     180 g (6.34 oz) (head)
     190 g (6.70 oz) (electronics)
    Safety standards
     EN 61010-1: 2001
     EN 61010-2-032: 2002
     EN 61010-031: 2002
     600 Vrms, Category III, Pollution Degree 2
     Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
    EMC standards
     EN 61326: 1998 A1, A2, & A3
    Dimensions
    HxWxD 116 mm x 68.5 mm x 30 mm (4.56 in x 2.69 in x 1.18 in)

     

    Our customers are also considering these Clamp Adapters

    https://www.fluke.com/en-gb

    • Measures current up to 2000A
    • Works with multimeters, recorders and data loggers
    • Max conductor diameter of 178mm allows the device to be used on thicker or more difficult conductors
    • CAT III 600V safety rated