Description
Fluke 64 MAX Infrared Thermometer
The Fluke 64 MAX Infrared Thermometer, is the most advanced of Fluke’s 60 MAX Infrared Thermometer series. It has a distance to spot ratio of 20:1 and a temperature accuracy of ±1°C or ±1% (whichever is greater with the 20:1 ratio).
The accuracy of the Fluke 64 MAX Infrared Thermometer is aided by its precise, rotating laser technology; this technology also facilitates the thermometer’s ability to perform repeat measurements quickly and accurately.
This instrument has been optimised for use in outdoor and/or harsh environments. To this end, it features a torch and large, backlit, LCD display facilitating the easy viewing of test environments and results. It is also resistant to dust ingress, splashes of water (IP 54) and will survive falls of up to 3m making it suitable for use in unpredictable, challenging, outdoor situations.
Further to this, the Fluke 64 MAX Infrared Thermometer is compact and lightweight; this ergonomic design makes it easy to use, store and carry.
Improving user efficiency is also at the forefront of this product’s design. It is operated by a single AA alkaline battery, yet will provide the user with up to thirty hours of battery life. In addition to this, the Fluke 64 MAX Infrared Thermometer can be set to record temperature measurements at particular times and intervals via the Auto Capture function. This removes the need for the user to be present, allowing him/her to complete other tasks while the Fluke 64 MAX takes the necessary, precise, reliable measurements.
The Fluke 64 MAX Infrared Thermometer is also capable of logging up to ninety-nine data points and can be set to display the minimum, maximum or average temperature; alternatively, it is also able to display the difference between two measured temperatures, making the recording and/or viewing of relevant values quick and easy. Moreover, high and low limit alarms facilitate the quick display of measurements which exceed the set parameters.
The Fluke 64 MAX Infrared Thermometer is a practical, accurate, cost-effective temperature measuring instrument.
Fluke 64 MAX Infrared Thermometer Technical Specifications
The table below details the Fluke 64 MAX’s technical specifications and functions as a comparison chart between the Fluke 64 MAX and its sister products the 62 MAX and 62 MAX.
Technical Specifications | 64 MAX | 62 MAX | 62 MAX |
Temperature Range | – 30 °C to 600 °C (-22 °F to 1112 °F) | – 30 °C to 650 °C (-22 °F to 1202 °F) | – 30 °C to 500 °C (-22 °F to 932 °F) |
Accuracy (calibration geometry with ambient temperature 23 °C /- 2 °C) | ± 1.0 °C or ± 1.0 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C ± 3.0 °C at -30 °C to -10 °C | ± 1.5 °C or ± 1.5 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C ± 3.0 °C at -30 °C to -10 °C | |
Optical Resolution | 20:1 (calculated at 90 % energy) | 12:1 (calculated at 90 % energy) | 10:1 (calculated at 90 % energy) |
Response Time (95 %) | < 500 ms (95 % of reading) | < 300 ms (95 % of reading) | < 500 ms (95 % of reading) |
Spectral response | 8 to 14 microns | ||
Emissivity | 0.10 to 1.00 | ||
Repeatability (% of reading) | ± 0.5 % of reading or ± 0.5 °C (whichever is greater) | ± 0.8 % of reading or ± 1 °C (whichever is greater) | |
Auto Capture | Set time and interval to capture up to 99 measurements | N/A | |
Internal Memory | 99 data point logging capability | N/A | |
Torch | Yes | N/A | |
Power | 1 AA alkaline battery | ||
Battery Life | 30 hours with laser and backlight on | 8 hours with laser and backlight on | 10 hours with laser and backlight on |
Weight | 255 g (8.99 oz) | ||
Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches | ||
Operating Temperature | 0 °C to 50 °C (32 °F to 122°F) | ||
Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F) (without battery) | ||
Operating Humidity | Non- condensing @ ≤ 10 °C (50 °F) ≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F) ≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F) ≤ 45 % RH @ 40 °C (104 °F) to 50 °C (122 °F) | ||
Operating Altitude | 2000 meters above mean sea level | ||
Storage Altitude | 12,000 meters above mean sea level | ||
Drop Test | 3 meters | ||
Implement Standard | Q/ASF01 | ||
Compliance | IEC 61010-1: Pollution Degree 2 | ||
Laser Safety | IEC 60825-1 Class 2, 650 nm, < 1 mW | ||
Ingress Protection Rating | IP 54 per IEC 60529 | ||
Warranty | 3 Years from Fluke |