    Amprobe AM-555 True-RMS Industrial Digital Multimeter

    The Amprobe AM-555 True-RMS Industrial Digital Multimeter is ideal for conducting critical measurements of HVAC, residential, industrial and electrical equipment. It is intended as a replacement for the Amprobe AM-550-EUR Industrial Digital Multimeter and has the following measurement capabilities:

    • AC Voltage: 1mV to 1000V
    • DC Voltage: 0.1mV to 1000V
    • AC Current: 0.1µA to 20A
    • DC Current:  0.1µA to 20A
    • Resistance: 0.1Ω to 60MΩ
    • Capacitance: 60nF to 60mF
    • Frequency:  1Hz to 60MHz
    • Temperature: -40°C to 1000°C

    The Amprobe AM-555-EUR True-RMS Industrial Digital Multimeter can also conduct duty cycles; diode tests and audible continuity tests. The Amprobe AM-555-EUR True-RMS Industrial Digital Multimeter is able to take true-RMS measurements and includes both an automatic and manual measurement range selection. It also features a low-pass filter and two temperature inputs.

    In addition to adjusting the measurement range to suit the user’s needs, he/she may also set the instrument to indicate particular measurements. The Amprobe AM-555-EUR True-RMS Industrial Digital Multimeter includes an integrated data memory (Data Hold) function which freezes the current value on screen, allowing the user to record the reading. Alternatively, the operator may utilise the MIN/MAX function to detect and view the minimum and maximum measurements read over the course of a testing period. The user may also take peak value measurements and relative value measurements.

    Readings are indicated on the illuminated display with 61 segment bar graph. This display, combined with the product’s integrated LED torch, makes the Amprobe AM-555-EUR True-RMS Industrial Digital Multimeter suitable for use in dark environments. Further to this, its robust housing and included carrying case ensure that this instrument remains practical even within rugged environments.

    Adding to this product’s resilience is its non-contact voltage detection which protects both the user and the Amprobe AM-555-EUR True-RMS Industrial Digital Multimeter from damage caused by live circuits.

    Finally, the Amprobe AM-555-EUR True-RMS Industrial Digital Multimeter’s Auto Power Off function extends its battery life, ensuring that it remains functional for longer.

    The Amprobe AM-555-EUR True-RMS Industrial Digital Multimeter is a comprehensive, practical instrument, ideal for taking measurements across a variety of environments.

    Specification AM-510-EUR AM-520-EUR AM-535-EUR AM-540-EUR AM-555-EUR
    Measurement category CAT III / 600V CAT III / 600V CAT III / 600V CAT IV / 600V, CAT III / 1000V CAT IV / 600V, CAT III / 1000V
    AC voltage 1 mV…600V 1 mV…600V 1 mV…600V 1 mV…1000 V 1 mV…1000 V
    Basic accuracy * ± (1.0 % rgd. 3 digits) ± (1.0 % rgd. 3 digits) ± (1.0 % rgd. 3 digits) ± (1.0 % rgd. 3 digits) ± (1.0 % rgd. 3 digits)
    Frequency range 45 Hz…400 Hz 45 Hz…400 Hz 45 Hz…400 Hz 45 Hz…1 kHz 45 Hz…1 kHz
    DC voltage 1 mV…600V 0.1 mV…600V 0.1 mV…600V 0.1 mV…1000 V 0.1 mV…1000 V
    Basic accuracy * ± (0.8 % rgd. 1 digits) ± (0.8 % rgd. 1 digits) ± (0.8 % rgd. 1 digits) ± (0.5 % rgd. 2 digits) ± (0.5 % rgd. 2 digits)
    Input resistance 10 MΩ 10 MΩ 10 MΩ 10 MΩ 10 MΩ
    Current AC 0.1 μA…10A 0.1 μA…10A 0.1 μA…20A** 0.1 μA…10A 0.1 μA…20A**
    Basic accuracy * ± (1.2 % rgd. 2 digits) ± (1.2 % rgd. 2 digits) ± (1.2 % rgd. 2 digits) ± (1.2 % rgd. 2 digits) ± (1.2 % rgd. 2 digits)
    Frequency range 45 Hz…400 Hz 45 Hz…400 Hz 45 Hz…400 Hz 45 Hz…1 kHz 45 Hz…1 kHz
    Current DC 0.1 μA…10A 0.1 μA…10A 0.1 μA…20A** 0.1 μA…10A 0.1 μA…20A**
    Basic accuracy * ± (1.0 % rgd 2 digits) ± (1.0 % rgd 2 digits) ± (1.0 % rgd 2 digits) ± (1.0 % rgd 2 digits) ± (1.0 % rgd 2 digits)
    Resistance 0.1 Ω…40 MΩ 0.1 Ω…40 MΩ 0.1 Ω…40 MΩ 0.1 Ω…60 MΩ 0.1 Ω…60 MΩ
    Basic accuracy * ± (1.2 % rgd. 2 digits) ± (1.2 % rgd. 2 digits) ± (1.2 % rgd. 2 digits) ± (1.2 % rgd. 2 digits) ± (1.2 % rgd. 2 digits)
    Capacitance 10 pF…100.0 µF 10 pF…4000 µF 10 pF…4000 µF 60.00 nF…60 mF 60.00 nF…60 mF
    Basic accuracy * ± (3 % rgd. 5 digits) ± (3 % rgd. 5 digits) ± (3 % rgd. 5 digits) ± (3 % rgd. 5 digits) ± (3 % rgd. 5 digits)
    Frequency 1,00 Hz…10 MHz 1,00 Hz…10 MHz 1,00 Hz…10 MHz 1,00 Hz…60 MHz 1,00 Hz…60 MHz
    Basic accuracy * ± (0.1 % rgd. 4 digits) ± (0.1 % rgd. 4 digits) ± (0.1 % rgd. 4 digits) ± (0.1 % rgd. 3 digits) ± (0.1 % rgd. 3 digits)
    Temperature -40…1000 °C -40…1000 °C -40…1000 °C -40…1000 °C
    Basic accuracy * ± (1.0 % rgd. 8 digits) ± (1.0 % rgd. 8 digits) ± (1.0 % rgd. 8 digits) ± (1.0 % rgd. 8 digits)
    Continuity R < 10 Ω R < 10 Ω R < 10 Ω R < 10 Ω R < 10 Ω
    General Specifications
    Display 3999 Digits 3999 Digits 3999 Digits 5999 Digits 5999 Digits
    Pollution degree 2
    Safety EN 61010, IEC 61010
    Power supply 9 V (6F22)
    Dimensions 182 x 90 x 45 mm
    Weight approx. 354 g (incl. battery)
    Scope of supply 2 x test leads, 1 x 9 V battery, 1 x user manual 2 x test leads, 1 x temperature probe, 1 x strap, 1 x 9 V battery, 1 x user manual 2 x test leads, 1 x temperature probe, 1 x strap, 1 x 9 V battery, 1 x user manual 2 x test leads, 2 x temperature probe, 1 x temperature adaptor 1 x strap, 1 x 9 V battery, 1 x user manual 2 x test leads, 2 x temperature probe, 1 x temperature adaptor 1 x strap, 1 x 9 V battery, 1 x user manual
    Notes *Basic accuracy refers to the best accuracy in the respective function

    **Max duration of measurement:

    8 to 10A: measure up to 20 minutes, 10 minutes off minimum between measurements

    > 10 to 20A: measure up to 30 seconds, 10 minutes off minimum between measurements

    • Multifunctional instrument ideal for taking critical measurements in HVAC, residential, industrial and electrical environments
    • AC Voltage: 1mV to 1000V
    • DC Voltage: 0.1mV to 1000V
    • AC Current: 0.1µA to 20A
    • DC Current:  0.1µA to 20A
    • Resistance: 0.1Ω to 60MΩ
    • Capacitance: 60nF to 60mF
    • Frequency:  1Hz to 60MHz
    • Temperature: -40°C to 1000°C
    • Duty cycles
    • Diode test
    • Audible continuity tests
    • True-RMS measurements
    • Automatic measurement range selection
    • Manual measurement range selection
    • Low-pass filter
    • Two temperature inputs
    • Data Hold
    • MIN/MAX
    • Peak value measurements
    • Relative value measurements
    • Illuminated display with 61 segment bar graph
    • Integrated LED torch
    • Robust casing
    • Included carry case
    • Non-contact voltage detection
    • Auto Power Off
    • Measurement category CAT IV / 600V, CAT III / 1000V
    • Replacement for the Amprobe AM-550-EUR Industrial Digital Multimeter
    • Amprobe AM-555-EUR True-RMS Industrial Digital Multimeter
    • 2x Test Leads
    • 2x Temperature Probe
    • 2x Temperature Adapter
    • 1x Strap
    • 1x 9V Battery
    • 1x Carry Case
    • 1x User Manual